Lithium UPS Line Interactive UPS 600VA-1200VA Simulated Sine wave with Lithium battery for home & office Appliances 600VA 800VA 1200VA
Lithium UPS Line Interactive UPS 600VA-1200VA Simulated Sine wave with Lithium battery for home & office Appliances 600VA 800VA 1200VA
RSUN OR OEM service Product origin China Delivery time 30days Line Interactive UPS modified Sine wave with Smart USB charger for PC, 600VA, 800VA, 1200VA for option. with long life LiFeO4 lithim battery inside, can provide power for your home devices via a USB Port directly, increases UPS availability by allowing USB charging function.
Line Interactive UPS with Simulated Sine wave with Smart USB charger for PC is available with 600VA, 800VA, 1200VA for option. These uninterrupted power suppy features with long life lifeP04 lithim battery in, can provide power for your home devices via a USB Port directly, increases UPS availability by allowing USB charging function.
Feature | |
1> CPU controlled | |
2> Auto re-starts when AC recovers | |
3> Silence setup | |
4> Automatic charging (offline charging) | |
5> Battery low voltage protection | |
6> Overload & short circuit protection | |
7> Wide input voltage range | |
8> Built-in BMS (Battery Management System) | |
9> Over temperature alarm and protection |
MODEL | VX-650Li | VX-800Li | VX-1200Li |
Capacity | 650VA | 800VA | 1200VA |
INPUT | |||
Input voltage | 110/120Vac or 220/230/240Vac | ||
Input voltage range | 84-145Vac / 145-290Vac | ||
Frequency range | 45-65Hz | ||
OUTPUT | |||
Output voltage | 110/120Vac or 220/230/240Vac | ||
Output voltage range | 102-132Vac / 200-255Vac | ||
Output frequency | 60±0.5Hz or 50±0.5Hz (Auto sensing ) | ||
Output wave form | PWM (Batt.mode) | ||
Transfer time | Typical 2-6ms, 10ms max | ||
BATTERY | |||
QTY. & capacity of battery | 315W/55WH | 410/75WH | 600W/150WH |
Charging period | 4-6 hours recover to 90% capacity | ||
backup time | 100W backup time ≥27min is equivalent to 7AH | 100W backup time ≥33min is equivalent to 9AH | 200W backup time ≥33min is equivalent to 9AH X2 |
battery type | LiFePO4 | ||
cycles life | lead acid battery 300 cycles / LiFePO4 battery 1000 cycles | ||
charging time | lead acid battery 8 hours / LiFePO4 battery 4 hours | ||
PROTECTION | |||
Full protection | BMS & temperature protection & Low voltage & overload & short circuit protection | ||
PHYSICAL | |||
Net weight(kg) | 3.0 | 3.3 | 5.0 |
Unit dimension(mm) | 225*85*141 | 305*85*141 | |
package size(mm) | 300*278*440 | 380*278*440 | |
ENVIRONMENT | |||
Environment of performance | Temperature 0℃-40℃, Humidity 20%-90% | ||
Noise level | ≤40dB(1m) | ||
MANAGEMENT | |||
LCD or LED, RJ45/11 & USB | optional |
Performance Characteristics:
1. Wide range of input voltage
The UPS can offer normal and stable service voltage under its input voltage range. When the input voltage is out of its range the machine will switch to battery mode automatically to keep the output power in order to protect the equipment, such as computers, ensure they will not be damaged by the over high or over low voltage, users can continue the operation of equipment for a while or save the data on computers while the power network is abnormal.
2. Wide range of AVR(Automatic voltage regulation)
In the product's input voltage range and under 3 steps of intelligent AVR function, it can provide a stable output voltage.
3. Automatic self detection when UPS on(LED).
Before the UPS on, red, yellow, blue LED will light up two times by cycle turns, after self detection UPS switch to AC mode/battery mode or working mode.
4. Silence function
In the "battery mode", shortly press the switch to turn off the buzzer. But the battery is about to run out or the load is too heavy, the buzzer sound cannot be muted.
5. Overload protection
In the battery mode, output voltage turn down correspondingly when it is overload, after the capacity of load is lower than the rated power then output voltage will back to rated value, it ensures the UPS will not shut down by abrupt overload which caused by surging current during the computer is working and other equipment is added.
6. Short circuit protection
When the mis-operation caused the load short circuit or computer failure (such as power tube breakdown of switch) cause short circuit, the UPS will shutdown automatically for protection.
7. The low current switch
This UPS adopts low current switch to extend the service life which is longer than conventional battery and high current switch in AC current path.
8. Automatic charging
There are two charging mode, charging time is faster than ordinary charging mode, higher efficiency, and greatly prolonging the service life of the battery.
9. With a bypass output
Independent bypass output socket for external printers or scanners of computer peripherals, with surge protection of the load.