Line interactive UPS with PWM output, offline UPS 500VA~1500VA, USB port, with plastic case

  • Line interactive UPS with PWM output, offline UPS 500VA~1500VA, USB port, with plastic case
  • Line interactive UPS with PWM output, offline UPS 500VA~1500VA, USB port, with plastic case
  • Line interactive UPS with PWM output, offline UPS 500VA~1500VA, USB port, with plastic case
Line interactive UPS with PWM output, offline UPS 500VA~1500VA, USB port, with plastic case

RSUN OR OEM service Product origin China Delivery time 30days Line interactive UPS with PWM output, modified sine wave, S series for home & office appliances, Uninterrupted Power Supply Unit, including power 500VA/650VA/850VA/1000VA/1200VA/1500VA for option, plastic or metal case, LED or LCD

Line interactive UPS with PWM Output offline UPS S series

for home, office appliances, LED or LCD, plastic or metal case, USB port

This series of Line interactive offline UPS S series is specifically designed for PC. It applies CPU integrated control technology and SMD(Surface Mount Deices)technology, which makes it perform satisfactorily and pleasing to the eye. It is an indispensable companion of PC, router and POS machines.

 

Feature:

*Capacity: 500VA~1500VA

*Auto re-starts when AC recovers

*Silence setup

*Automatic charging(offline charging)

*Battery low voltage protection

*Overload&short circuit protection

*CUP controlled

*Wide input voltage range

*Optional RJ45/11&USB port

*Application: PC, work station, small communication equipment.,etc.

 

Photos:

 

Specifications:

Model # S-500 S-650 S-800 S-1000 S-1200 S-1500
Capacity 500VA/300W 650VA/390W 800VA/480W 1000VA/600W 1200VA/720W 1500VA/900W
AVR No, can add 3 steps of AVR, CPU controlled
INPUT
Input voltage range 230V:175~265±5Vac 220/230/240V:145~290Vac±5Vac
110V/120V: 90~132±5Vac 110V/120V: 85~150Vac±5Vac
Input frequency range 50Hz / 60Hz (Auto sensing)
OUTPUT
Output voltage range 230V: 175~265±5Vac 220/230/240V:200~255Vac
110V/120V: 90~132±5Vac 110V/120V: 102~132Vac
Output frequency (DC mode) 50±0.5Hz / 60±0.5Hz
Wave form PWM (DC Mode)
Transfer time Typical 2~6ms, Max.10ms.
BATTERY
QTY & capacity of battery 1 pc*12V4.5Ah 1 pc*12V7Ah 1 pc*12V9Ah 2 pcs*12V7Ah 2 pcs*12V7Ah 2 pcs*12V9Ah
Charging period 4~6 hours recover to 90% capacity
PROTECTION & FUNCTION
PROTECTION 1. Battery low voltage protection
2. Overload protection
3. Short circuit protection
FUNCTION 1. Auto re-starts when AC recovers
2. Silence setup
3. Automatic charging (offline charging)
MANAGEMENT
RJ45/11 & USB Optional, refer to customers' requires.
PHYSICAL
Unit dimension (mm) 314*97*143 345*146*162
Color box dimension (mm) 370*145*230 435*223*242
Master box dimension (mm) 380*312*485 466*450*264
Pcs in one master carton 4 2
Gross weight (1pc, kg) 4.2 4.9 6.2 11.2 13.0 15.0
Net weight (1pc, kg) 4.0 4.6 5.8 11.0 12.8 14.8
Loading capacity (20' ctrn) 2160 pcs 960 pcs
Loading capacity (40' GP) 4440 pcs 1920 pcs

 

Performance Characteristics:

1. Wide range of input voltage
The UPS can offer normal and stable service voltage under its input voltage range. When the input voltage is out of its range the machine will switch to battery mode automatically to keep the output power in order to protect the equipment, such as computers, ensure they will not be damaged by the over high or over low voltage, users can continue the operation of equipment for a while or save the data on computers while the power network is abnormal.
2. Wide range of AVR(Automatic voltage regulation)
In the product's input voltage range and under 3 steps of intelligent AVR function, it can provide a stable output voltage.
3. Automatic self detection when UPS on(LED).
Before the UPS on, red, yellow, blue LED will light up two times by cycle turns, after self detection UPS switch to AC mode/battery mode or working mode.
4. Silence function
In the "battery mode", shortly press the switch to turn off the buzzer. But the battery is about to run out or the load is too heavy, the buzzer sound cannot be muted.
5. Overload protection
In the battery mode, output voltage turn down correspondingly when it is overload, after the capacity of load is lower than the rated power then output voltage will back to rated value, it ensures the UPS will not shut down by abrupt overload which caused by surging current during the computer is working and other equipment is added.
6. Short circuit protection
When the mis-operation caused the load short circuit or computer failure (such as power tube breakdown of switch) cause short circuit, the UPS will shutdown automatically for protection.
7. The low current switch
This UPS adopts low current switch to extend the service life which is longer than conventional battery and high current switch in AC current path.
8. Automatic charging
There are two charging mode, charging time is faster than ordinary charging mode, higher efficiency, and greatly prolonging the service life of the battery.
9. With a bypass output
Independent bypass output socket for external printers or scanners of computer peripherals, with surge protection of the load.
Get the latest price? We'll respond as soon as possible(within 12 hours)
close left right